Back to home page

Project CMSSW displayed by LXR

 
 

    


File indexing completed on 2025-03-26 01:50:58

0001 import FWCore.ParameterSet.Config as cms
0002 
0003 process = cms.Process("FedCablingReader")
0004 
0005 process.MessageLogger = cms.Service("MessageLogger",
0006     threshold = cms.untracked.string('INFO'),
0007     debugModules = cms.untracked.vstring(''),
0008     #destinations = cms.untracked.vstring('cout'),
0009     destinations = cms.untracked.vstring('cablingReader.log')
0010 )
0011 
0012 process.source = cms.Source("EmptySource",
0013     numberEventsInRun = cms.untracked.uint32(1),
0014     firstRun = cms.untracked.uint32(1)
0015 )
0016 
0017 process.maxEvents = cms.untracked.PSet(
0018     input = cms.untracked.int32(1)
0019 )
0020 
0021 process.poolDBESSource = cms.ESSource("PoolDBESSource",
0022    DBParameters = cms.PSet(
0023         messageLevel = cms.untracked.int32(2),
0024         authenticationPath = cms.untracked.string('/afs/cern.ch/cms/DB/conddb')
0025     ),
0026     connect = cms.string('sqlite_file:SiStripConditionsDBFile.db'),
0027     toGet = cms.VPSet(cms.PSet(
0028         record = cms.string('SiStripFedCablingRcd'),
0029         tag = cms.string('SiStripFedCabling_30X')
0030     ))
0031 )
0032 
0033 process.load("Configuration.StandardSequences.FrontierConditions_GlobalTag_cff")
0034 from Configuration.AlCa.autoCond import autoCond
0035 process.GlobalTag.globaltag = autoCond['phase1_2022_design']
0036 print("taking geometry from %s" % process.GlobalTag.globaltag.value())
0037 process.load("Configuration.StandardSequences.GeometryDB_cff")
0038 
0039 process.SiStripConnectivity = cms.ESProducer("SiStripConnectivity")
0040 process.SiStripRegionConnectivity = cms.ESProducer("SiStripRegionConnectivity",
0041                                                    EtaDivisions = cms.untracked.uint32(20),
0042                                                    PhiDivisions = cms.untracked.uint32(20),
0043                                                    EtaMax = cms.untracked.double(2.5)
0044 )
0045 
0046 process.prefer_SiStripConnectivity = cms.ESPrefer("SiStripConnectivity", "sistripconn")
0047 process.prefer_SiStripCabling = cms.ESPrefer("PoolDBESSource", "poolDBESSource")
0048 
0049 process.fedcablingreader = cms.EDAnalyzer("SiStripFedCablingReader",
0050                                           PrintFecCabling = cms.untracked.bool(True),
0051                                           PrintDetCabling = cms.untracked.bool(True),
0052                                           PrintRegionCabling = cms.untracked.bool(True)
0053 )
0054 
0055 process.p1 = cms.Path(process.fedcablingreader)
0056 
0057