Line Code
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100 101 102 103 104 105 106 107 108 109 110 111 112 113 114 115 116 117 118 119 120 121 122 123 124 125 126 127 128 129 130 131 132 133 134 135 136 137 138 139 140 141 142 143 144 145 146 147 148 149 150 151 152 153 154 155 156 157 158 159 160 161 162 163 164 165 166 167 168 169
# Import configurations
import FWCore.ParameterSet.Config as cms

process = cms.Process("test")

process.load("CalibTracker.SiStripDCS.MessLogger_cfi")

process.SiStripConfigDb = cms.Service("SiStripConfigDb",
    ConfDb = cms.untracked.string('username/password@cms_omds_nolb'),
    TNS_ADMIN = cms.untracked.string('.'),
    UsingDb = cms.untracked.bool(True),
    Partitions = cms.untracked.PSet(
        TPDD = cms.untracked.PSet(
            PartitionName = cms.untracked.string('TP_08-AUG-2008_1'),
            ForceVersions = cms.untracked.bool(True),
            FecVersion    = cms.untracked.vuint32(430,2),
            DcuDetIdsVersion = cms.untracked.vuint32(9,0)
        ),
        TMDD = cms.untracked.PSet(
            PartitionName = cms.untracked.string('TM_08-AUG-2008_1'),
            ForceVersions = cms.untracked.bool(True),
            FecVersion    = cms.untracked.vuint32(428,1),
            DcuDetIdsVersion = cms.untracked.vuint32(9,0)
        ),
        TIDD = cms.untracked.PSet(
            PartitionName = cms.untracked.string('TI_08-AUG-2008_1'),
            ForceVersions = cms.untracked.bool(True),
            FecVersion    = cms.untracked.vuint32(427,1),
            DcuDetIdsVersion = cms.untracked.vuint32(9,0)
        ),
        TODD = cms.untracked.PSet(
            PartitionName = cms.untracked.string('TO_08-AUG-2008_1'),
            ForceVersions = cms.untracked.bool(True),
            FecVersion    = cms.untracked.vuint32(415,3),
            DcuDetIdsVersion = cms.untracked.vuint32(9,0)
        ),
        TEPD2 = cms.untracked.PSet(
            PartitionName = cms.untracked.string('TE_27-JUN-2008_2'),
            ForceVersions = cms.untracked.bool(True),
            DcuPsuMapVersion = cms.untracked.vuint32(211, 2)
        ),
        TMPD = cms.untracked.PSet(
            PartitionName = cms.untracked.string('TE_17-JUN-2008_12'),
            ForceVersions = cms.untracked.bool(True),
            DcuPsuMapVersion = cms.untracked.vuint32(163, 1)
        ),
        TEPD1 = cms.untracked.PSet(
            PartitionName = cms.untracked.string('TE_24-JUN-2008_2'),
            ForceVersions = cms.untracked.bool(True),
            DcuPsuMapVersion = cms.untracked.vuint32(204, 1)
        ),
        TEPD4 = cms.untracked.PSet(
            PartitionName = cms.untracked.string('TE_30-JUN-2008_1'),
            ForceVersions = cms.untracked.bool(True),
            DcuPsuMapVersion = cms.untracked.vuint32(229, 1)
        ),
        TEPD3 = cms.untracked.PSet(
            PartitionName = cms.untracked.string('TE_27-JUN-2008_4'),
            ForceVersions = cms.untracked.bool(True),
            DcuPsuMapVersion = cms.untracked.vuint32(214, 1)
        ),
        TPPD = cms.untracked.PSet(
            PartitionName = cms.untracked.string('TE_17-JUN-2008_11'),
            ForceVersions = cms.untracked.bool(True),
            DcuPsuMapVersion = cms.untracked.vuint32(162, 1)
        ),
        TIPD = cms.untracked.PSet(
            PartitionName = cms.untracked.string('TI_17-JUN-2008_2'),
            ForceVersions = cms.untracked.bool(True),
            DcuPsuMapVersion = cms.untracked.vuint32(157, 1)
        ),
        TIPD2 = cms.untracked.PSet(
            PartitionName = cms.untracked.string('TI_18-JUN-2008_1'),
            ForceVersions = cms.untracked.bool(True),
            DcuPsuMapVersion = cms.untracked.vuint32(165, 1)
        ),
        TIPD3 = cms.untracked.PSet(
            PartitionName = cms.untracked.string('TI_18-JUN-2008_10'),
            ForceVersions = cms.untracked.bool(True),
            DcuPsuMapVersion = cms.untracked.vuint32(179, 1)
        ),
        TIPD4 = cms.untracked.PSet(
            PartitionName = cms.untracked.string('TI_20-JUN-2008_1'),
            ForceVersions = cms.untracked.bool(True),
            DcuPsuMapVersion = cms.untracked.vuint32(192, 1)
        ),
        TIPD5 = cms.untracked.PSet(
            PartitionName = cms.untracked.string('TI_27-JUN-2008_1'),
            ForceVersions = cms.untracked.bool(True),
            DcuPsuMapVersion = cms.untracked.vuint32(212, 1)
        ),
        TIPD6 = cms.untracked.PSet(
            PartitionName = cms.untracked.string('TI_27-JUN-2008_3'),
            ForceVersions = cms.untracked.bool(True),
            DcuPsuMapVersion = cms.untracked.vuint32(218, 1)
        ),
        TOPD = cms.untracked.PSet(
            PartitionName = cms.untracked.string('TO_18-JUN-2008_1_TEST_1'),
            ForceVersions = cms.untracked.bool(True),
            DcuPsuMapVersion = cms.untracked.vuint32(177, 1)
        ),
        TOPD2 = cms.untracked.PSet(
            PartitionName = cms.untracked.string('TO_18-JUN-2008_2'),
            ForceVersions = cms.untracked.bool(True),
            DcuPsuMapVersion = cms.untracked.vuint32(178, 1)
        ),
        TOPD3 = cms.untracked.PSet(
            PartitionName = cms.untracked.string('TO_30-JUN-2008_1'),
            ForceVersions = cms.untracked.bool(True),
            DcuPsuMapVersion = cms.untracked.vuint32(228, 1)
        )
    )
)

process.maxEvents = cms.untracked.PSet(
    input = cms.untracked.int32(1)
)
process.source = cms.Source("EmptySource",
    numberEventsInRun = cms.untracked.uint32(1),
    firstRun = cms.untracked.uint32(1)
)

process.load("CondCore.DBCommon.CondDBCommon_cfi")
process.CondDBCommon.connect = cms.string('oracle://cms_omds_nolb/username')

process.SiStripModuleHVBuilder = cms.Service("SiStripModuleHVBuilder",
    onlineDB = cms.untracked.string('oracle://cms_omds_nolb/username'),
    authPath = cms.untracked.string('.'),
# Format for date/time vector:  year, month, day, hour, minute, second, nanosecond                              
    Tmin = cms.untracked.vint32(2009, 6, 17, 6, 0, 0, 0),
    Tmax = cms.untracked.vint32(2009, 6, 17, 21, 0, 0, 0),
# Do NOT change this unless you know what you are doing!
    TSetMin = cms.untracked.vint32(2007, 11, 26, 0, 0, 0, 0),                                             
# queryType can be either STATUSCHANGE or LASTVALUE                              
    queryType = cms.untracked.string('STATUSCHANGE'),
# if reading lastValue from file put insert file name here                              
    lastValueFile = cms.untracked.string(''),
# flag to show if you are reading from file for lastValue or not                              
    lastValueFromFile = cms.untracked.bool(False),
# flag to toggle debug output
    debugModeOn = cms.untracked.bool(False)
)

process.PoolDBOutputService = cms.Service("PoolDBOutputService",
    BlobStreamerName = cms.untracked.string('TBufferBlobStreamingService'),
    DBParameters = cms.PSet(
        messageLevel = cms.untracked.int32(2),
        authenticationPath = cms.untracked.string('/afs/cern.ch/cms/DB/conddb')
    ),
    timetype = cms.untracked.string('timestamp'),
    connect = cms.string('sqlite_file:dbfile.db'),
    toPut = cms.VPSet(cms.PSet(
        record = cms.string('SiStripDetVOffRcd'),
        tag = cms.string('SiStripDetVOff_Fake_31X')
    )),
    logconnect = cms.untracked.string('sqlite_file:logfile.db')
)

process.siStripPopConModuleHV = cms.EDAnalyzer("SiStripPopConModuleHV",
    record = cms.string('SiStripDetVOffRcd'),
    loggingOn= cms.untracked.bool(True),
    SinceAppendMode=cms.bool(True),
    Source = cms.PSet(
        name = cms.untracked.string('default')
    )                                        
)

process.p = cms.Path(process.siStripPopConModuleHV)