1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
|
import FWCore.ParameterSet.Config as cms
import FWCore.ParameterSet.VarParsing as VarParsing
process = cms.Process("SiStripQualityStatisticsCabling")
#prepare options
options = VarParsing.VarParsing("analysis")
options.register ('cablingTagName',
"SiStripFedCabling_GR10_v1_hlt",
VarParsing.VarParsing.multiplicity.singleton, # singleton or list
VarParsing.VarParsing.varType.string, # string, int, or float
"Cabling DB tag name")
options.register ('runNumber',
1,
VarParsing.VarParsing.multiplicity.singleton, # singleton or list
VarParsing.VarParsing.varType.int, # string, int, or float
"Run Number")
options.parseArguments()
process.MessageLogger = cms.Service("MessageLogger",
cout = cms.untracked.PSet(
threshold = cms.untracked.string('WARNING')
),
log_cabling = cms.untracked.PSet(
threshold = cms.untracked.string('INFO'),
default = cms.untracked.PSet(limit=cms.untracked.int32(0)),
SiStripQualityStatistics = cms.untracked.PSet(limit=cms.untracked.int32(100000))
),
destinations = cms.untracked.vstring('log_cabling','cout'),
categories = cms.untracked.vstring('SiStripQualityStatistics')
)
process.source = cms.Source("EmptyIOVSource",
timetype = cms.string('runnumber'),
firstValue= cms.uint64(options.runNumber),
lastValue= cms.uint64(options.runNumber),
interval = cms.uint64(1)
)
process.maxEvents = cms.untracked.PSet(
input = cms.untracked.int32(1)
)
#-------------------------------------------------
# Calibration
#-------------------------------------------------
process.load("Configuration.Geometry.GeometryIdeal_cff") # needed because the GlobalTag is NOT used
process.load("CondCore.DBCommon.CondDBCommon_cfi") # needed because the GlobalTag is NOT used
process.CondDBCommon.connect='frontier://FrontierProd/CMS_CONDITIONS'
process.poolDBESSource=cms.ESSource("PoolDBESSource",
process.CondDBCommon,
toGet =cms.VPSet(
cms.PSet(
record=cms.string('SiStripFedCablingRcd'),
tag =cms.string(options.cablingTagName)
)
)
)
#process.load("CalibTracker.Configuration.Tracker_DependentRecords_forGlobalTag_nofakes_cff") )
process.sistripconn = cms.ESProducer("SiStripConnectivity") # needed because the GlobalTag is NOT used
# Include masking #
process.load("CalibTracker.SiStripESProducers.SiStripQualityESProducer_cfi")
process.siStripQualityESProducer.ListOfRecordToMerge=cms.VPSet(
cms.PSet(record=cms.string('SiStripDetCablingRcd'),tag=cms.string(''))
)
process.siStripQualityESProducer.ReduceGranularity = cms.bool(False)
#-------------------------------------------------
# Services for the TkHistoMap
#-------------------------------------------------
process.load("DQM.SiStripCommon.TkHistoMap_cff")
from CalibTracker.SiStripQuality.siStripQualityStatistics_cfi import siStripQualityStatistics
process.stat = siStripQualityStatistics.clone(
TkMapFileName=cms.untracked.string("TkMapBadComponents_Cabling.png") #available filetypes: .pdf .png .jpg .svg
)
process.p = cms.Path(process.stat)
|