<?xml version="1.0" encoding="UTF-8"?>
<?proc-inst-1 'foo' ?>

<dbelements xmlns::xsi="http://www.w3.org/2001/XMLSchema-instance"
            xsi:noNamespaceSchemaLocation="prova.xsd">

  <me>
    <th2d title="Temperature H4" xbins="17" xfrom="0." xto="17." ybins="10" yfrom="0." yto="10." ncycle="1" loop="170"/>
    <query name="addToTableList"  arg="CHANNELVIEW" />
    <query name="addToTableList"  arg="DCU_CAPSULE_TEMP_DAT" />
    <query name="addToTableList"  arg="DCU_IOV" />
    <query name="addToOutputList" arg="CHANNELVIEW.ID2" />
    <query name="addToOutputList" arg="cast( 0.5 + floor((CHANNELVIEW.ID2-1) / 10 ) as float )" alias="X" />
    <query name="addToOutputList" arg="cast( 0.5 + mod((CHANNELVIEW.ID2-1) , 10 ) as float )" alias="Y" />
    <query name="addToOutputList" arg="cast( DCU_CAPSULE_TEMP_DAT.CAPSULE_TEMP as float )" alias="Z" />
    <query name="setCondition" arg="DCU_CAPSULE_TEMP_DAT.IOV_ID = (select max(IOV_ID) from DCU_IOV, DCU_TAG, LOCATION_DEF where DCU_IOV.TAG_ID=DCU_TAG.TAG_ID and LOCATION_DEF.DEF_ID = DCU_TAG.LOCATION_ID and LOCATION_DEF.LOCATION='H4') and DCU_IOV.IOV_ID=DCU_CAPSULE_TEMP_DAT.IOV_ID and CHANNELVIEW.LOGIC_ID=DCU_CAPSULE_TEMP_DAT.LOGIC_ID" />;
    <query name="addToOrderList" arg="CHANNELVIEW.ID2" />
  </me> 

  <me>
    <th2d title="Temperature H4B" xbins="17" xfrom="0." xto="17." ybins="10" yfrom="0." yto="10." ncycle="1" loop="170"/>
    <query name="addToTableList"  arg="CHANNELVIEW" />
    <query name="addToTableList"  arg="DCU_CAPSULE_TEMP_DAT" />
    <query name="addToTableList"  arg="DCU_IOV" />
    <query name="addToOutputList" arg="CHANNELVIEW.ID2" />
    <query name="addToOutputList" arg="cast( 0.5 + floor((CHANNELVIEW.ID2-1) / 10 ) as float )" alias="X" />
    <query name="addToOutputList" arg="cast( 0.5 + mod((CHANNELVIEW.ID2-1) , 10 ) as float )" alias="Y" />
    <query name="addToOutputList" arg="cast( DCU_CAPSULE_TEMP_DAT.CAPSULE_TEMP as float )" alias="Z" />
    <query name="setCondition" arg="DCU_CAPSULE_TEMP_DAT.IOV_ID = (select max(IOV_ID) from DCU_IOV, DCU_TAG, LOCATION_DEF where DCU_IOV.TAG_ID=DCU_TAG.TAG_ID and LOCATION_DEF.DEF_ID = DCU_TAG.LOCATION_ID and LOCATION_DEF.LOCATION='H4B') and DCU_IOV.IOV_ID=DCU_CAPSULE_TEMP_DAT.IOV_ID and CHANNELVIEW.LOGIC_ID=DCU_CAPSULE_TEMP_DAT.LOGIC_ID" />;
    <query name="addToOrderList" arg="CHANNELVIEW.ID2" />
  </me> 

  <me>
    <th2d title="Temperature H2" xbins="17" xfrom="0." xto="17." ybins="10" yfrom="0." yto="10." ncycle="1" loop="170"/>
    <query name="addToTableList"  arg="CHANNELVIEW" />
    <query name="addToTableList"  arg="DCU_CAPSULE_TEMP_DAT" />
    <query name="addToTableList"  arg="DCU_IOV" />
    <query name="addToOutputList" arg="CHANNELVIEW.ID2" />
    <query name="addToOutputList" arg="cast( 0.5 + floor((CHANNELVIEW.ID2-1) / 10 ) as float )" alias="X" />
    <query name="addToOutputList" arg="cast( 0.5 + mod((CHANNELVIEW.ID2-1) , 10 ) as float )" alias="Y" />
    <query name="addToOutputList" arg="cast( DCU_CAPSULE_TEMP_DAT.CAPSULE_TEMP as float )" alias="Z" />
    <query name="setCondition" arg="DCU_CAPSULE_TEMP_DAT.IOV_ID = (select max(IOV_ID) from DCU_IOV, DCU_TAG, LOCATION_DEF where DCU_IOV.TAG_ID=DCU_TAG.TAG_ID and LOCATION_DEF.DEF_ID = DCU_TAG.LOCATION_ID and LOCATION_DEF.LOCATION='H2') and DCU_IOV.IOV_ID=DCU_CAPSULE_TEMP_DAT.IOV_ID and CHANNELVIEW.LOGIC_ID=DCU_CAPSULE_TEMP_DAT.LOGIC_ID" />;
    <query name="addToOrderList" arg="CHANNELVIEW.ID2" />
  </me> 