Line Code
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100 101 102 103 104 105 106 107 108 109 110 111 112 113 114 115 116 117 118 119 120 121 122 123 124 125 126 127 128 129 130 131 132 133 134 135 136 137 138 139 140 141 142 143 144 145 146 147 148 149 150 151 152 153 154 155 156 157 158 159 160 161 162 163 164 165 166 167 168 169 170 171 172 173 174 175 176 177 178 179 180 181 182 183 184 185 186 187 188 189 190 191 192 193 194 195 196 197 198 199 200 201 202 203 204 205 206 207 208 209 210
# L1 Trigger DQM sequence (L1T)
#
#   authors previous versions - see CVS
#
#   V.M. Ghete 2011-05-25 revised version of L1 Trigger DQM


import FWCore.ParameterSet.Config as cms

from Configuration.Eras.Era_Run3_cff import Run3
process = cms.Process("DQM", Run3)


#----------------------------
# Event Source
#
# for live online DQM in P5
process.load("DQM.Integration.config.inputsource_cfi")
from DQM.Integration.config.inputsource_cfi import options
#
# for testing in lxplus
#process.load("DQM.Integration.config.fileinputsource_cfi")
#from DQM.Integration.config.fileinputsource_cfi import options

#----------------------------
# DQM Environment
 
process.load("DQM.Integration.config.environment_cfi")
process.dqmEnv.subSystemFolder = 'L1T'
process.dqmSaver.tag = 'L1T'
process.dqmSaver.runNumber = options.runNumber
# process.dqmSaverPB.tag = 'L1T'
# process.dqmSaverPB.runNumber = options.runNumber

#
# references needed

# Condition for P5 cluster
process.load("DQM.Integration.config.FrontierCondition_GT_cfi")
process.GlobalTag.RefreshEachRun = True
# Condition for lxplus: change and possibly customise the GT
#from Configuration.AlCa.GlobalTag import GlobalTag as gtCustomise
#process.GlobalTag = gtCustomise(process.GlobalTag, 'auto:run3s_data', '')

#process.load("Configuration.StandardSequences.GeometryRecoDB_cff")
process.load("Configuration.StandardSequences.GeometryRecoDB_cff")

#-------------------------------------
# sequences needed for L1 trigger DQM
#

# standard unpacking sequence 
process.load("Configuration.StandardSequences.RawToDigi_Data_cff")    

# L1 Trigger sequences 

# l1tMonitor and l1tMonitorEndPathSeq
process.load("DQM.L1TMonitor.L1TMonitor_cff")    

# L1 trigger synchronization module - it uses also HltHighLevel filter
process.load("DQM.L1TMonitor.L1TSync_cff")    


# l1tMonitorClient and l1tMonitorClientEndPathSeq
process.load("DQM.L1TMonitorClient.L1TMonitorClient_cff")    

#-------------------------------------
# paths & schedule for L1 Trigger DQM
#

# TODO define a L1 trigger L1TriggerRawToDigi in the standard sequence 
# to avoid all these remove
process.rawToDigiPath = cms.Path(process.RawToDigi)
#
process.RawToDigi.remove("siPixelDigis")
process.RawToDigi.remove("siStripDigis")
process.RawToDigi.remove("scalersRawToDigi")
process.RawToDigi.remove("castorDigis")
# for GCT, unpack all five samples
process.gctDigis.numberOfGctSamplesToUnpack = 5

#if ( process.runType.getRunType() == process.runType.pp_run_stage1 or process.runType.getRunType() == process.runType.cosmic_run_stage1):
process.gtDigis.DaqGtFedId = 809
#else:
#    process.gtDigis.DaqGtFedId = cms.untracked.int32(813)
# 
process.l1tMonitorPath = cms.Path(process.l1tMonitorOnline)

# separate L1TSync path due to the use of the HltHighLevel filter
process.l1tSyncPath = cms.Path(process.l1tSyncHltFilter+process.l1tSync)

#
process.l1tMonitorClientPath = cms.Path(process.l1tMonitorClient)

#
process.l1tMonitorEndPath = cms.EndPath(process.l1tMonitorEndPathSeq)

#
process.l1tMonitorClientEndPath = cms.EndPath(process.l1tMonitorClientEndPathSeq)

#
process.dqmEndPath = cms.EndPath(
                                 process.dqmEnv *
                                 process.dqmSaver #*
                                 # process.dqmSaverPB
                                 )

#
process.schedule = cms.Schedule(process.rawToDigiPath,
                                process.l1tMonitorPath,
                                process.l1tSyncPath,
                                #process.l1tMonitorClientPath,
                                #process.l1tMonitorEndPath,
                                #process.l1tMonitorClientEndPath,
                                process.dqmEndPath
                                )

#---------------------------------------------

# examples for quick fixes in case of troubles 
#    please do not modify the commented lines
#


#
# turn on verbosity in L1TEventInfoClient
#
# process.l1tEventInfoClient.verbose = cms.untracked.bool(True)


# remove module(s) or system sequence from l1tMonitorPath
#        quality test disabled also
#
process.l1tMonitorOnline.remove(process.bxTiming)
process.l1tMonitorOnline.remove(process.l1tBPTX)

#process.l1tMonitorOnline.remove(process.l1tLtc)

process.l1tMonitorOnline.remove(process.l1tDttf)

process.l1tMonitorOnline.remove(process.l1tCsctf) 

process.l1tMonitorOnline.remove(process.l1tRpctf)

process.l1tMonitorOnline.remove(process.l1tGmt)

#process.l1tMonitorOnline.remove(process.l1tGt) 

#process.l1tMonitorOnline.remove(process.l1ExtraDqmSeq)

process.l1tMonitorOnline.remove(process.l1tRate)

process.l1tMonitorOnline.remove(process.l1tRctRun1)

#process.l1tMonitorOnline.remove(process.l1tGctSeq)


# remove module(s) or system sequence from l1tMonitorEndPath
#
process.l1tMonitorEndPathSeq.remove(process.l1s)
process.l1tMonitorEndPathSeq.remove(process.l1tscalers)

#
process.schedule.remove(process.l1tSyncPath)

#--------------------------------------------------
# Heavy Ion Specific Fed Raw Data Collection Label
#--------------------------------------------------

print("Running with run type = ", process.runType.getRunType())
process.castorDigis.InputLabel = "rawDataCollector"
process.csctfDigis.producer = "rawDataCollector"
process.dttfDigis.DTTF_FED_Source = "rawDataCollector"
process.ecalDigisCPU.InputLabel = "rawDataCollector"
process.ecalPreshowerDigis.sourceTag = "rawDataCollector"
process.gctDigis.inputLabel = "rawDataCollector"
process.gtDigis.DaqGtInputTag = "rawDataCollector"
process.gtEvmDigis.EvmGtInputTag = "rawDataCollector"
process.hcalDigis.InputLabel = "rawDataCollector"
process.muonCSCDigis.InputObjects = "rawDataCollector"
process.muonDTDigis.inputLabel = "rawDataCollector"
process.muonRPCDigis.InputLabel = "rawDataCollector"
process.scalersRawToDigi.scalersInputTag = "rawDataCollector"
process.siPixelDigis.InputLabel = "rawDataCollector"
process.siStripDigis.ProductLabel = "rawDataCollector"
process.bxTiming.FedSource = "rawDataCollector"
process.l1s.fedRawData = "rawDataCollector"
    
if (process.runType.getRunType() == process.runType.hi_run):
    process.castorDigis.InputLabel = "rawDataRepacker"
    process.csctfDigis.producer = "rawDataRepacker"
    process.dttfDigis.DTTF_FED_Source = "rawDataRepacker"
    process.ecalDigisCPU.InputLabel = "rawDataRepacker"
    process.ecalPreshowerDigis.sourceTag = "rawDataRepacker"
    process.gctDigis.inputLabel = "rawDataRepacker"
    process.gtDigis.DaqGtInputTag = "rawDataRepacker"
    process.gtEvmDigis.EvmGtInputTag = "rawDataRepacker"
    process.hcalDigis.InputLabel = "rawDataRepacker"
    process.muonCSCDigis.InputObjects = "rawDataRepacker"
    process.muonDTDigis.inputLabel = "rawDataRepacker"
    process.muonRPCDigis.InputLabel = "rawDataRepacker"
    process.scalersRawToDigi.scalersInputTag = "rawDataRepacker"
    process.siPixelDigis.InputLabel = "rawDataRepacker"
    process.siStripDigis.ProductLabel = "rawDataRepacker"
    process.bxTiming.FedSource = "rawDataRepacker"
    process.l1s.fedRawData = "rawDataRepacker"

### process customizations included here
from DQM.Integration.config.online_customizations_cfi import *
process = customise(process)