Line Code
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100 101 102 103 104 105 106 107 108 109 110 111 112 113 114 115 116 117 118 119 120 121 122 123 124 125 126 127 128 129 130 131 132 133 134 135 136 137 138 139 140 141 142 143 144 145 146
import FWCore.ParameterSet.Config as cms
import FWCore.ParameterSet.VarParsing as VarParsing
import glob
import os
import os,sys,getopt,glob,cx_Oracle,subprocess

cmsswbase = os.path.expandvars("$CMSSW_BASE/")
inputPath = '/raid/fff'

##### to understand the run type by means of connecting the the CONFDB
conn_str = os.path.expandvars("$CONFDB")
conn     = cx_Oracle.connect(conn_str)
e        = conn.cursor()
e.execute('select RUNMODE from run where runnumber = RUNNUMBER')
runmode = e.fetchall()
runtype = -1;
for result in runmode:
    runtype = int(result[0]);
conn.close()


process = cms.Process("SRC")

process.load("DQM.SiStripCommon.MessageLogger_cfi")

process.load("DQM.SiStripCommon.DaqMonitorROOTBackEnd_cfi")

process.load("OnlineDB.SiStripConfigDb.SiStripConfigDb_cfi")
process.SiStripConfigDb.UsingDb = True                    
process.SiStripConfigDb.ConfDb = 'user/password@account'
process.SiStripConfigDb.Partitions.PrimaryPartition.PartitionName = 'DBPART'
process.SiStripConfigDb.Partitions.PrimaryPartition.RunNumber     = RUNNUMBER
process.SiStripConfigDb.TNS_ADMIN = '/etc'

process.SiStripCondObjBuilderFromDb = cms.Service("SiStripCondObjBuilderFromDb")
process.SiStripCondObjBuilderFromDb.SiStripDetInfoFile = cms.FileInPath("CalibTracker/SiStripCommon/data/SiStripDetInfo.dat")
process.SiStripCondObjBuilderFromDb.UseFEC = cms.untracked.bool(True)
process.SiStripCondObjBuilderFromDb.UseFED = cms.untracked.bool(True)

process.FedCablingFromConfigDb = cms.ESSource("SiStripFedCablingBuilderFromDb",
    CablingSource = cms.untracked.string('UNDEFINED')  
)

process.PedestalsFromConfigDb = cms.ESSource("SiStripPedestalsBuilderFromDb")
process.NoiseFromConfigDb = cms.ESSource("SiStripNoiseBuilderFromDb")
process.sistripconn = cms.ESProducer("SiStripConnectivity")

process.load("Geometry.CMSCommonData.cmsIdealGeometryXML_cfi")
process.load("Geometry.TrackerNumberingBuilder.trackerTopology_cfi")
process.load("Geometry.TrackerGeometryBuilder.trackerParameters_cfi")

process.FastMonitoringService = cms.Service("FastMonitoringService",
        sleepTime = cms.untracked.int32(1),
        microstateDefPath = cms.untracked.string( cmsswbase+'/src/EventFilter/Utilities/plugins/microstatedef.jsd'),
        fastMicrostateDefPath = cms.untracked.string( cmsswbase+'/src/EventFilter/Utilities/plugins/microstatedeffast.jsd'),
        fastName = cms.untracked.string( 'fastmoni' ),
        slowName = cms.untracked.string( 'slowmoni' )
)

process.EvFDaqDirector = cms.Service("EvFDaqDirector",
        runNumber = cms.untracked.uint32(RUNNUMBER),
        buBaseDir = cms.untracked.string(inputPath),
        directorIsBu = cms.untracked.bool(False),
        testModeNoBuilderUnit = cms.untracked.bool(False)
)

process.source = cms.Source("FedRawDataInputSource",
        runNumber = cms.untracked.uint32(RUNNUMBER),
        getLSFromFilename = cms.untracked.bool(True),
        testModeNoBuilderUnit = cms.untracked.bool(False),
        verifyAdler32 = cms.untracked.bool(True),
        verifyChecksum = cms.untracked.bool(True),
        useL1EventID = cms.untracked.bool(True),
        eventChunkSize = cms.untracked.uint32(16),
        numBuffers = cms.untracked.uint32(2),
        eventChunkBlock = cms.untracked.uint32(1),
        fileListMode = cms.untracked.bool(True),
        fileNames = cms.untracked.vstring()
)

process.maxEvents = cms.untracked.PSet( input = cms.untracked.int32(-1) )

### for run types != from DAQ SCOPE Modes
if runtype != 15:
    process.load("EventFilter.SiStripRawToDigi.FedChannelDigis_cfi")
    process.FedChannelDigis.UnpackBadChannels = cms.bool(True)
    process.FedChannelDigis.DoAPVEmulatorCheck = cms.bool(True)
    process.FedChannelDigis.LegacyUnpacker = cms.bool(False)
    process.FedChannelDigis.ProductLabel = cms.InputTag("rawDataCollector")
else:
    process.load('DQM.SiStripMonitorHardware.SiStripSpyUnpacker_cfi')
    process.load('DQM.SiStripMonitorHardware.SiStripSpyDigiConverter_cfi')
    process.load('DQM.SiStripMonitorHardware.SiStripSpyEventSummaryProducer_cfi')    
    ## * Scope digi settings                                                                                                                                                                     
    process.SiStripSpyUnpacker.FEDIDs = cms.vuint32()                   #use a subset of FEDs or leave empty for all.                                                                                  
    process.SiStripSpyUnpacker.InputProductLabel = cms.InputTag('rawDataCollector')
    process.SiStripSpyUnpacker.AllowIncompleteEvents = True
    process.SiStripSpyUnpacker.StoreCounters = True
    process.SiStripSpyUnpacker.StoreScopeRawDigis = cms.bool(True)      # Note - needs to be True for use in other modules.                                                                       
    ## * Module digi settings                                                                                                                                                                         
    process.SiStripSpyDigiConverter.InputProductLabel = cms.InputTag('SiStripSpyUnpacker','ScopeRawDigis')
    process.SiStripSpyDigiConverter.StorePayloadDigis = True
    process.SiStripSpyDigiConverter.StoreReorderedDigis = True
    process.SiStripSpyDigiConverter.StoreModuleDigis = True
    process.SiStripSpyDigiConverter.StoreAPVAddress = True
    process.SiStripSpyDigiConverter.MinDigiRange = 100
    process.SiStripSpyDigiConverter.MaxDigiRange = 1024
    process.SiStripSpyDigiConverter.MinZeroLight = 0
    process.SiStripSpyDigiConverter.MaxZeroLight = 1024
    process.SiStripSpyDigiConverter.MinTickHeight = 0
    process.SiStripSpyDigiConverter.MaxTickHeight = 1024
    process.SiStripSpyDigiConverter.ExpectedPositionOfFirstHeaderBit = 0
    process.SiStripSpyDigiConverter.DiscardDigisWithWrongAPVAddress = False
    process.SiStripSpyEventSummary.RawDataTag = cms.InputTag('rawDataCollector')

process.load("DQM.SiStripCommissioningSources.CommissioningHistos_cfi")
process.CommissioningHistos.CommissioningTask = 'UNDEFINED'
process.CommissioningHistos.PedsFullNoiseParameters.NrEvToSkipAtStart = 100
process.CommissioningHistos.PedsFullNoiseParameters.NrEvForPeds       = 3000
process.CommissioningHistos.PedsFullNoiseParameters.FillNoiseProfile  = True

outfilename = inputPath+"/run"+"RUNNUMBER"+"/run"+"RUNNUMBER"+".root"
process.out = cms.OutputModule("PoolOutputModule",
  fileName = cms.untracked.string(outfilename),
  outputCommands = cms.untracked.vstring("drop *", "keep FEDRawDataCollection_*_*_*")
)

if runtype != 15:
    process.p = cms.Path(process.FedChannelDigis*process.CommissioningHistos)
else:
    
    process.SiStripSpyEventSummary.RunType = cms.uint32(runtype)
    process.CommissioningHistos.InputModuleLabel = 'SiStripSpyDigiConverter'  # output label from spy converter                                                                                        
    process.CommissioningHistos.InputModuleLabelAlt = cms.string('SiStripSpyUnpacker')
    process.CommissioningHistos.SummaryInputModuleLabel = 'SiStripSpyEventSummary'
    process.CommissioningHistos.isSpy = cms.bool(True)
    process.CommissioningHistos.PartitionName = cms.string('DBPART')

    process.p = cms.Path(process.SiStripSpyUnpacker*process.SiStripSpyDigiConverter*process.SiStripSpyEventSummary*process.CommissioningHistos)

process.e = cms.EndPath(process.out)

fnames = glob.glob(inputPath+"/run"+"RUNNUMBER"+"/*ls00*.raw")
for f in fnames :
        process.source.fileNames.extend(cms.untracked.vstring('file:'+f))