1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
|
import FWCore.ParameterSet.Config as cms
import FWCore.ParameterSet.VarParsing as VarParsing
process = cms.Process("Reader")
options = VarParsing.VarParsing("analysis")
options.register ('logDestination',
"",
VarParsing.VarParsing.multiplicity.singleton, # singleton or list
VarParsing.VarParsing.varType.string, # string, int, or float
"log file")
options.register ('qualityLogDestination',
"",
VarParsing.VarParsing.multiplicity.singleton, # singleton or list
VarParsing.VarParsing.varType.string, # string, int, or float
"quality log file")
options.register ('runInfoTag',
"",
VarParsing.VarParsing.multiplicity.singleton, # singleton or list
VarParsing.VarParsing.varType.string, # string, int, or float
"RunInfo tag name")
options.register ('cablingTag',
"",
VarParsing.VarParsing.multiplicity.singleton, # singleton or list
VarParsing.VarParsing.varType.string, # string, int, or float
"cabling tag name")
options.register ('cablingConnectionString',
"",
VarParsing.VarParsing.multiplicity.singleton, # singleton or list
VarParsing.VarParsing.varType.string, # string, int, or float
"Cabling connection string")
options.register ('runinfoConnectionString',
"",
VarParsing.VarParsing.multiplicity.singleton, # singleton or list
VarParsing.VarParsing.varType.string, # string, int, or float
"RunInfo connection string")
options.register ('MonitorCumulative',
False,
VarParsing.VarParsing.multiplicity.singleton, # singleton or list
VarParsing.VarParsing.varType.bool, # string, int, or float
"Cumulative Monitoring?")
options.register ('outputRootFile',
"",
VarParsing.VarParsing.multiplicity.singleton, # singleton or list
VarParsing.VarParsing.varType.string, # string, int, or float
"output root file")
options.register ('runNumber',
0,
VarParsing.VarParsing.multiplicity.singleton, # singleton or list
VarParsing.VarParsing.varType.int, # string, int, or float
"run number")
options.parseArguments()
process.MessageLogger = cms.Service("MessageLogger",
debugModules = cms.untracked.vstring(''),
# insertLog = cms.untracked.PSet(
# threshold = cms.untracked.string('INFO')
# ),
destinations = cms.untracked.vstring(options.logDestination,
options.qualityLogDestination
# options.cablingLogDestination,
# options.condLogDestination
), #Reader, cout
categories = cms.untracked.vstring('SiStripQualityStatistics'
# 'SiStripQualityDQM',
# 'SiStripFedCablingReader',
# 'DummyCondObjContentPrinter',
)
)
setattr(process.MessageLogger,options.logDestination,cms.untracked.PSet(threshold = cms.untracked.string('INFO')))
setattr(process.MessageLogger,options.qualityLogDestination,cms.untracked.PSet(
threshold = cms.untracked.string('INFO'),
default = cms.untracked.PSet(limit=cms.untracked.int32(0)),
SiStripQualityStatistics = cms.untracked.PSet(limit=cms.untracked.int32(100000))
# SiStripQualityDQM = cms.untracked.PSet(limit=cms.untracked.int32(100000))
)
)
process.maxEvents = cms.untracked.PSet(
input = cms.untracked.int32(-1)
)
process.source = cms.Source("EmptyIOVSource",
firstValue = cms.uint64(options.runNumber),
lastValue = cms.uint64(options.runNumber),
timetype = cms.string('runnumber'),
interval = cms.uint64(1)
)
# the DB Geometry is NOT used because in this cfg only one tag is taken from the DB and no GT is used. To be fixed if this is a problem
process.load('Configuration.Geometry.GeometryExtended_cff')
process.TrackerTopologyEP = cms.ESProducer("TrackerTopologyEP")
process.load("Geometry.TrackerGeometryBuilder.trackerParameters_cfi")
process.poolDBESSourceRunInfo = cms.ESSource("PoolDBESSource",
DBParameters = cms.PSet(
messageLevel = cms.untracked.int32(1), # it used to be 2
authenticationPath = cms.untracked.string('/afs/cern.ch/cms/DB/conddb')
),
connect = cms.string(options.runinfoConnectionString),
toGet = cms.VPSet(cms.PSet(
record = cms.string('RunInfoRcd'),
tag = cms.string(options.runInfoTag)
)
)
)
process.poolDBESSourceFedCabling = cms.ESSource("PoolDBESSource",
DBParameters = cms.PSet(
messageLevel = cms.untracked.int32(1),
authenticationPath = cms.untracked.string('/afs/cern.ch/cms/DB/conddb')
),
connect = cms.string(options.cablingConnectionString),
toGet = cms.VPSet(cms.PSet(
record = cms.string('SiStripFedCablingRcd'),
tag = cms.string(options.cablingTag)
)
)
)
process.DQMStore = cms.Service("DQMStore",
verbose = cms.untracked.int32(1)
)
process.load("DQM.SiStripMonitorSummary.SiStripMonitorCondData_cfi")
process.CondDataMonitoring.OutputFileName = options.outputRootFile
process.CondDataMonitoring.MonitorSiStripPedestal = False
process.CondDataMonitoring.MonitorSiStripNoise = False
process.CondDataMonitoring.MonitorSiStripQuality = True
process.CondDataMonitoring.MonitorSiStripCabling = False
process.CondDataMonitoring.MonitorSiStripApvGain = False
process.CondDataMonitoring.MonitorSiStripLorentzAngle = False
process.CondDataMonitoring.MonitorSiStripBackPlaneCorrection = False
process.CondDataMonitoring.MonitorSiStripLowThreshold = False
process.CondDataMonitoring.MonitorSiStripHighThreshold = False
process.CondDataMonitoring.OutputMEsInRootFile = True
process.CondDataMonitoring.FillConditions_PSet.OutputSummaryAtLayerLevelAsImage = True
process.CondDataMonitoring.FillConditions_PSet.OutputSummaryProfileAtLayerLevelAsImage = False # This should be saved only in case of LA (because for LA no SummaryAtLayerLevel is available)
process.CondDataMonitoring.FillConditions_PSet.OutputCumulativeSummaryAtLayerLevelAsImage = options.MonitorCumulative
process.CondDataMonitoring.FillConditions_PSet.HistoMaps_On = False
process.CondDataMonitoring.FillConditions_PSet.TkMap_On = True # This is just for test until TkMap is included in all classes!!! Uncomment!!!!
process.CondDataMonitoring.FillConditions_PSet.ActiveDetIds_On = True # This should be set to False only for Lorentz Angle
process.CondDataMonitoring.SiStripPedestalsDQM_PSet.FillSummaryAtLayerLevel = True
process.CondDataMonitoring.SiStripNoisesDQM_PSet.FillSummaryAtLayerLevel = True
process.CondDataMonitoring.SiStripQualityDQM_PSet.FillSummaryAtLayerLevel = True
process.CondDataMonitoring.SiStripApvGainsDQM_PSet.FillSummaryAtLayerLevel = True
process.CondDataMonitoring.SiStripLowThresholdDQM_PSet.FillSummaryAtLayerLevel = True
process.CondDataMonitoring.SiStripHighThresholdDQM_PSet.FillSummaryAtLayerLevel = True
process.CondDataMonitoring.SiStripCablingDQM_PSet.CondObj_fillId = 'ProfileAndCumul'
process.CondDataMonitoring.SiStripPedestalsDQM_PSet.CondObj_fillId = 'onlyProfile'
process.CondDataMonitoring.SiStripNoisesDQM_PSet.CondObj_fillId = 'onlyCumul'
process.CondDataMonitoring.SiStripQualityDQM_PSet.CondObj_fillId = 'onlyProfile'
process.CondDataMonitoring.SiStripApvGainsDQM_PSet.CondObj_fillId = 'ProfileAndCumul'
process.CondDataMonitoring.SiStripLorentzAngleDQM_PSet.CondObj_fillId = 'ProfileAndCumul'
process.CondDataMonitoring.SiStripBackPlaneCorrectionDQM_PSet.CondObj_fillId = 'ProfileAndCumul'
process.CondDataMonitoring.SiStripLowThresholdDQM_PSet.CondObj_fillId = 'onlyProfile'
process.CondDataMonitoring.SiStripHighThresholdDQM_PSet.CondObj_fillId = 'onlyProfile'
## --- TkMap specific Configurable options:
process.CondDataMonitoring.SiStripQualityDQM_PSet.TkMap_On = True
process.CondDataMonitoring.SiStripQualityDQM_PSet.TkMapName = 'QualityTkMap.png'
process.CondDataMonitoring.SiStripQualityDQM_PSet.minValue = 0.
process.CondDataMonitoring.SiStripQualityDQM_PSet.maxValue = 100.
process.CondDataMonitoring.SiStripCablingDQM_PSet.TkMap_On = True
process.CondDataMonitoring.SiStripCablingDQM_PSet.TkMapName = 'CablingTkMap.png'
process.CondDataMonitoring.SiStripCablingDQM_PSet.minValue = 0.
process.CondDataMonitoring.SiStripCablingDQM_PSet.maxValue = 6.
process.CondDataMonitoring.SiStripPedestalsDQM_PSet.TkMap_On = True
process.CondDataMonitoring.SiStripPedestalsDQM_PSet.TkMapName = 'PedestalTkMap.png'
process.CondDataMonitoring.SiStripPedestalsDQM_PSet.minValue = 0.
process.CondDataMonitoring.SiStripPedestalsDQM_PSet.maxValue = 400.
process.CondDataMonitoring.SiStripNoisesDQM_PSet.TkMap_On = True
process.CondDataMonitoring.SiStripNoisesDQM_PSet.TkMapName = 'NoiseTkMap.png'
process.CondDataMonitoring.SiStripNoisesDQM_PSet.minValue = 3.
process.CondDataMonitoring.SiStripNoisesDQM_PSet.maxValue = 9.
process.CondDataMonitoring.SiStripApvGainsDQM_PSet.TkMap_On = True
process.CondDataMonitoring.SiStripApvGainsDQM_PSet.TkMapName = 'GainTkMap.png'
process.CondDataMonitoring.SiStripApvGainsDQM_PSet.minValue = 0.
process.CondDataMonitoring.SiStripApvGainsDQM_PSet.maxValue = 1.5
process.CondDataMonitoring.SiStripLorentzAngleDQM_PSet.TkMap_On = True
process.CondDataMonitoring.SiStripLorentzAngleDQM_PSet.TkMapName = 'LorentzAngleTkMap.png'
process.CondDataMonitoring.SiStripLorentzAngleDQM_PSet.minValue = 0.01
process.CondDataMonitoring.SiStripLorentzAngleDQM_PSet.maxValue = 0.03
process.CondDataMonitoring.SiStripBackPlaneCorrectionDQM_PSet.TkMap_On = True
process.CondDataMonitoring.SiStripBackPlaneCorrectionDQM_PSet.TkMapName = 'BackPlaneCorrectionTkMap.png'
process.CondDataMonitoring.SiStripBackPlaneCorrectionDQM_PSet.minValue = 0.00
process.CondDataMonitoring.SiStripBackPlaneCorrectionDQM_PSet.maxValue = 0.10
process.CondDataMonitoring.SiStripLowThresholdDQM_PSet.TkMap_On = True
process.CondDataMonitoring.SiStripLowThresholdDQM_PSet.TkMapName = 'LowThresholdTkMap.png'
process.CondDataMonitoring.SiStripLowThresholdDQM_PSet.minValue = 0.
process.CondDataMonitoring.SiStripLowThresholdDQM_PSet.maxValue = 10.
process.CondDataMonitoring.SiStripHighThresholdDQM_PSet.TkMap_On = True
process.CondDataMonitoring.SiStripHighThresholdDQM_PSet.TkMapName = 'HighThresholdTkMap.png'
process.CondDataMonitoring.SiStripHighThresholdDQM_PSet.minValue = 0.
process.CondDataMonitoring.SiStripHighThresholdDQM_PSet.maxValue = 10.
process.p1 = cms.Path(process.CondDataMonitoring)
process.SiStripQualityESProducer = cms.ESProducer("SiStripQualityESProducer",
ReduceGranularity = cms.bool(False),
PrintDebugOutput = cms.bool(False),
UseEmptyRunInfo = cms.bool(True),
ListOfRecordToMerge = cms.VPSet(
cms.PSet(
record = cms.string('RunInfoRcd'),
tag = cms.string('')
),
cms.PSet(
record = cms.string('SiStripDetCablingRcd'),
tag = cms.string('')
)
)
)
process.sistripconn = cms.ESProducer("SiStripConnectivity")
from CalibTracker.SiStripQuality.siStripQualityStatistics_cfi import siStripQualityStatistics
process.stat = siStripQualityStatistics.clone()
process.e = cms.EndPath(process.stat)
|