1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
|
import FWCore.ParameterSet.Config as cms
process = cms.Process("HLT")
process.load("FWCore.MessageService.MessageLogger_cfi")
process.options = cms.untracked.PSet(
wantSummary = cms.untracked.bool(True)
)
process.maxEvents = cms.untracked.PSet(
input = cms.untracked.int32(10)
)
process.source = cms.Source("PoolSource",
fileNames = cms.untracked.vstring('file:/scratch/bachtis/RECO-ZTT-GEN-SIM-DIGI-0013.root')
)
process.load("Configuration.StandardSequences.GeometryPilot2_cff")
process.load("Configuration.StandardSequences.MagneticField_cff")
# Conditions: fake or frontier
# process.load("Configuration.StandardSequences.FakeConditions_cff")
process.load("Configuration.StandardSequences.FrontierConditions_GlobalTag_cff")
process.GlobalTag.globaltag = 'STARTUP_V4::All'
process.load("Configuration.StandardSequences.L1Emulator_cff")
# Choose a menu/prescale/mask from one of the choices
# in L1TriggerConfig.L1GtConfigProducers.Luminosity
process.load("Configuration.StandardSequences.L1TriggerDefaultMenu_cff")
# run HLT
process.load("SimGeneral.HepPDTESSource.pythiapdt_cfi")
process.load("HLTrigger.Configuration.HLT_2E30_cff")
process.hltL1gtTrigReport = cms.EDAnalyzer( "L1GtTrigReport",
UseL1GlobalTriggerRecord = cms.bool( False ),
L1GtRecordInputTag = cms.InputTag( "hltGtDigis" )
)
process.hltTrigReport = cms.EDAnalyzer( "HLTrigReport",
HLTriggerResults = cms.InputTag( 'TriggerResults','','HLT' )
)
process.HLTAnalyzerEndpath = cms.EndPath( process.hltL1gtTrigReport + process.hltTrigReport )
process.schedule.append(process.HLTAnalyzerEndpath)
process.load("FWCore.MessageService.MessageLogger_cfi")
process.DQMStore = cms.Service("DQMStore")
#Load DQM Services
process.load("DQMServices.Core.DQM_cfg")
process.load("DQMServices.Components.DQMEnvironment_cfi")
#Reconfigure Environment and saver
#process.dqmEnv.subSystemFolder = cms.untracked.string('HLT/HLTTAU')
#process.DQM.collectorPort = 9091
#process.DQM.collectorHost = cms.untracked.string('pcwiscms10')
process.dqmSaver.saveByRun = cms.untracked.int32(-1)
process.dqmSaver.saveAtJobEnd = cms.untracked.bool(True)
process.dqmSaver.workflow = cms.untracked.string('/A/N/C')
process.dqmSaver.forceRunNumber = cms.untracked.int32(123)
#Load the Validation
process.load("HLTriggerOffline.Tau.Validation.HLTTauValidation_cff")
#Load The Post processor
process.load("HLTriggerOffline.Tau.Validation.HLTTauPostValidation_cfi")
#Define the Paths
process.validation = cms.Path(process.HLTTauVal)
process.postProcess = cms.EndPath(process.HLTTauPostVal+process.dqmSaver)
#process.postProcess = cms.EndPath(process.dqmSaver)
process.schedule.append(process.validation)
process.schedule.append(process.postProcess)
|