File indexing completed on 2024-04-06 11:59:43
0001 import FWCore.ParameterSet.Config as cms
0002
0003 process = cms.Process("APVGAIN")
0004
0005 process.load('Configuration.StandardSequences.GeometryRecoDB_cff')
0006 process.load("Configuration.StandardSequences.FrontierConditions_GlobalTag_cff")
0007
0008
0009 process.load("CalibTracker.SiStripESProducers.SiStripQualityESProducer_cfi")
0010 process.load("CalibTracker.SiStripESProducers.fake.SiStripDetVOffFakeESSource_cfi")
0011 process.es_prefer_fakeSiStripDetVOff = cms.ESPrefer("SiStripDetVOffFakeESSource","siStripDetVOffFakeESSource")
0012
0013 process.MessageLogger = cms.Service("MessageLogger",
0014 cout = cms.untracked.PSet( threshold = cms.untracked.string('ERROR') ),
0015 destinations = cms.untracked.vstring('cout')
0016 )
0017
0018 process.options = cms.untracked.PSet(
0019 Rethrow = cms.untracked.vstring('ProductNotFound'),
0020 fileMode = cms.untracked.string('FULLMERGE')
0021 )
0022
0023 process.maxEvents = cms.untracked.PSet(
0024 input = cms.untracked.int32(1)
0025 )
0026
0027 from Configuration.AlCa.GlobalTag import GlobalTag
0028 process.GlobalTag = GlobalTag(process.GlobalTag, 'XXX_GT_XXX', '')
0029
0030 from FileList_cfg import calibTreeList
0031
0032 process.load("CalibTracker.SiStripChannelGain.computeGain_cff")
0033 process.SiStripCalib.FirstSetOfConstants = cms.untracked.bool(False)
0034 process.SiStripCalibValidation.CalibrationLevel = cms.untracked.int32(0)
0035 process.SiStripCalibValidation.saveSummary = cms.untracked.bool(True)
0036 process.SiStripCalibValidation.calibrationMode = cms.untracked.string( 'XXX_CALMODE_XXX' )
0037
0038
0039 if(XXX_PCL_XXX):
0040 process.SiStripCalibValidation.AlgoMode = cms.untracked.string('PCL')
0041 process.SiStripCalibValidation.harvestingMode = cms.untracked.bool(True)
0042 process.SiStripCalib.DQMdir = cms.untracked.string('XXX_DQMDIR_XXX')
0043 process.source = cms.Source("PoolSource",
0044 secondaryFileNames = cms.untracked.vstring(),
0045 fileNames = calibTreeList,
0046 processingMode = cms.untracked.string('RunsAndLumis')
0047 )
0048 else:
0049 process.SiStripCalibValidation.InputFiles = calibTreeList
0050 process.source = cms.Source("EmptyIOVSource",
0051 timetype = cms.string('runnumber'),
0052 interval = cms.uint64(1),
0053 firstValue = cms.uint64(XXX_FIRSTRUN_XXX),
0054 lastValue = cms.uint64(XXX_LASTRUN_XXX)
0055 )
0056
0057 process.TFileService = cms.Service("TFileService",
0058 fileName = cms.string('Validation_Tree.root')
0059 )
0060
0061 process.DQMStore = cms.Service("DQMStore")
0062
0063 if(XXX_PCL_XXX):
0064 process.load("DQMServices.Components.DQMFileSaver_cfi")
0065 process.dqmSaver.convention = 'Offline'
0066 process.dqmSaver.workflow = '/Express/PCLTest/ALCAPROMPT'
0067
0068 from DQMServices.Components.EDMtoMEConverter_cfi import *
0069
0070 process.EDMtoMEConvertSiStripGains = EDMtoMEConverter.clone()
0071 process.EDMtoMEConvertSiStripGains.lumiInputTag = cms.InputTag("MEtoEDMConvertSiStripGains","MEtoEDMConverterLumi")
0072 process.EDMtoMEConvertSiStripGains.runInputTag = cms.InputTag("MEtoEDMConvertSiStripGains","MEtoEDMConverterRun")
0073
0074 process.EDMtoMEConvertSiStripGainsAAG = EDMtoMEConverter.clone()
0075 process.EDMtoMEConvertSiStripGainsAAG.lumiInputTag = cms.InputTag("MEtoEDMConvertSiStripGainsAAG","MEtoEDMConverterLumi")
0076 process.EDMtoMEConvertSiStripGainsAAG.runInputTag = cms.InputTag("MEtoEDMConvertSiStripGainsAAG","MEtoEDMConverterRun")
0077
0078
0079 ConvertersSiStripGains = cms.Sequence( process.EDMtoMEConvertSiStripGains +
0080 process.EDMtoMEConvertSiStripGainsAAG )
0081
0082 process.p = cms.Path( ConvertersSiStripGains * process.SiStripCalibValidation * process.dqmSaver)
0083
0084 else:
0085 process.p = cms.Path(process.SiStripCalibValidation)
0086
0087
0088