File indexing completed on 2024-11-25 02:29:11
0001
0002
0003
0004 import FWCore.ParameterSet.Config as cms
0005
0006
0007 process = cms.Process('CALIB')
0008 process.load('Configuration/StandardSequences/MagneticField_cff')
0009 process.load('Configuration.Geometry.GeometryRecoDB_cff')
0010 process.load('Configuration.StandardSequences.FrontierConditions_GlobalTag_cff')
0011
0012 from Configuration.AlCa.GlobalTag import GlobalTag
0013 process.GlobalTag = GlobalTag(process.GlobalTag, "auto:run3_data_PromptAnalysis")
0014
0015 process.load('FWCore.MessageService.MessageLogger_cfi')
0016 process.load('Configuration.StandardSequences.Services_cff')
0017
0018 process.maxEvents = cms.untracked.PSet(input=cms.untracked.int32(-1))
0019
0020 process.source = cms.Source("PoolSource",
0021 fileNames = cms.untracked.vstring("/store/express/Run2023F/StreamExpress/ALCARECO/SiStripCalMinBias-Express-v1/000/373/710/00000/e2df2f78-b95a-4f33-ae22-add59aa2903f.root"))
0022
0023 process.options = cms.untracked.PSet( wantSummary = cms.untracked.bool(True) )
0024 process.MessageLogger.cerr.FwkReport.reportEvery = 10000
0025
0026 inTracks = cms.InputTag("ALCARECOSiStripCalMinBias")
0027
0028 process.load('CalibTracker.SiStripCommon.prescaleEvent_cfi')
0029 process.load('CalibTracker.Configuration.Filter_Refit_cff')
0030
0031 process.CalibrationTracks.src = inTracks
0032
0033 tracksForCalib = cms.InputTag("CalibrationTracksRefit")
0034
0035 process.prescaleEvent.prescale = 1
0036
0037 process.TkCalSeq = cms.Sequence(process.prescaleEvent*process.MeasurementTrackerEvent*process.trackFilterRefit)
0038
0039 process.load("PhysicsTools.NanoAOD.nano_cff")
0040 process.load("PhysicsTools.NanoAOD.NanoAODEDMEventContent_cff")
0041
0042
0043 from PhysicsTools.NanoAOD.common_cff import *
0044
0045 process.tracksTable = cms.EDProducer("SimpleTrackFlatTableProducer",
0046 src=tracksForCalib,
0047 cut=cms.string(""),
0048 name=cms.string("track"),
0049 doc=cms.string("SiStripCalMinBias ALCARECO tracks"),
0050 singleton=cms.bool(False),
0051 extension=cms.bool(False),
0052 variables=cms.PSet(
0053 chi2ndof=Var("chi2()/ndof", float),
0054 pt=Var("pt()", float),
0055 hitsvalid=Var("numberOfValidHits()", int),
0056 phi=Var("phi()", float),
0057 eta=Var("eta()", float),
0058 )
0059 )
0060 process.load("CalibTracker.SiStripCommon.tkInstLumiTable_cfi")
0061 process.tkInstLumiTable.extension = True
0062 process.load("CalibTracker.SiStripCommon.siStripGainCalibTable_cfi")
0063 process.siStripGainCalibTable.Tracks = tracksForCalib
0064
0065 process.nanoCTPath = cms.Path(process.TkCalSeq*
0066 process.nanoMetadata*process.tkInstLumiTable
0067 *process.tracksTable
0068 *process.siStripGainCalibTable
0069 )
0070
0071 process.out = cms.OutputModule("NanoAODOutputModule",
0072 fileName=cms.untracked.string("CalibTreeMC_nano_G2.root"),
0073 outputCommands=process.NANOAODEventContent.outputCommands
0074 )
0075
0076 process.end = cms.EndPath(process.out)