0001 from __future__ import print_function
0002 import sys
0003 # $Id: physics_dqm_sourceclient-live_cfg.py,v 1.11 2012/02/13 15:09:30 lilopera Exp $
0004 
0005 import FWCore.ParameterSet.Config as cms
0006 
0007 if 'runkey=hi_run' in sys.argv:
0008   from Configuration.Eras.Era_Run3_pp_on_PbPb_approxSiStripClusters_cff import Run3_pp_on_PbPb_approxSiStripClusters
0009   process = cms.Process("Physics", Run3_pp_on_PbPb_approxSiStripClusters)
0010 else:
0011   from Configuration.Eras.Era_Run3_cff import Run3
0012   process = cms.Process("Physics", Run3)
0013 
0014 #----------------------------
0015 # Event Source
0016 #-----------------------------
0017 
0018 # for live online DQM in P5
0019 process.load("DQM.Integration.config.inputsource_cfi")
0020 from DQM.Integration.config.inputsource_cfi import options
0021 
0022 # for testing in lxplus
0023 #process.load("DQM.Integration.config.fileinputsource_cfi")
0024 #from DQM.Integration.config.fileinputsource_cfi import options
0025 
0026 #----------------------------
0027 # DQM Environment
0028 #-----------------------------
0029 
0030 process.load("DQM.Integration.config.environment_cfi")
0031 process.dqmEnv.subSystemFolder = 'Physics'
0032 process.dqmSaver.tag = 'Physics'
0033 process.dqmSaver.runNumber = options.runNumber
0034 process.dqmSaverPB.tag = 'Physics'
0035 process.dqmSaverPB.runNumber = options.runNumber
0036 
0037 # 0=random, 1=physics, 2=calibration, 3=technical
0038 process.hltTriggerTypeFilter = cms.EDFilter("HLTTriggerTypeFilter",
0039     SelectedTriggerType = cms.int32(1)
0040 )
0041 
0042 #---- for P5 (online) DB access
0043 process.load("DQM.Integration.config.FrontierCondition_GT_cfi")
0044 # Condition for lxplus: change and possibly customise the GT
0045 #from Configuration.AlCa.GlobalTag import GlobalTag as gtCustomise
0046 #process.GlobalTag = gtCustomise(process.GlobalTag, 'auto:run3_data', '')
0047 
0048 process.load('Configuration.StandardSequences.GeometryRecoDB_cff')
0049 process.load('Configuration/StandardSequences/MagneticField_AutoFromDBCurrent_cff')
0050 process.load('DQM/Physics/qcdLowPtDQM_cfi')
0051 
0052 #process.dump = cms.EDAnalyzer('EventContentAnalyzer')
0053 
0054 process.p = cms.Path(
0055     process.hltTriggerTypeFilter *
0056     process.myRecoSeq1  *
0057     process.myRecoSeq2  *
0058 #    process.dump *
0059     process.qcdLowPtDQM *
0060     process.dqmEnv *
0061     process.dqmSaver *
0062     process.dqmSaverPB
0063 )
0064 
0065 process.siPixelDigis.cpu.InputLabel = "rawDataCollector"
0066 
0067 ### process customizations included here
0068 from DQM.Integration.config.online_customizations_cfi import *
0069 process = customise(process)
0070 
0071 #--------------------------------------------------
0072 # Heavy Ion Specific Fed Raw Data Collection Label
0073 #--------------------------------------------------
0074 
0075 print("Running with run type = ", process.runType.getRunType())
0076 
0077 if (process.runType.getRunType() == process.runType.hi_run):
0078     process.siPixelDigis.cpu.InputLabel = "rawDataRepacker"