File indexing completed on 2024-04-06 12:08:52
0001 import FWCore.ParameterSet.Config as cms
0002
0003 from DQMServices.Core.DQMEDAnalyzer import DQMEDAnalyzer
0004 PedsMon = DQMEDAnalyzer('SiStripMonitorPedestals',
0005 OutputMEsInRootFile = cms.bool(False),
0006 StripQualityLabel = cms.string(''),
0007 RunTypeFlag = cms.string('CalculatedPlotsOnly'),
0008
0009 DigiProducer = cms.string('siStripDigis'),
0010 PedestalsPSet = cms.PSet(
0011 MaskDeadCut = cms.double(0.7),
0012 MaskCalculationFlag = cms.int32(1),
0013 NumberOfEventsForInit = cms.int32(200),
0014 MaskNoiseCut = cms.double(6.0),
0015 useDB = cms.bool(False),
0016 NumCMstripsInGroup = cms.int32(128),
0017 CutToAvoidSignal = cms.double(3.0),
0018 NumberOfEventsForIteration = cms.int32(100),
0019 CalculatorAlgorithm = cms.string('TT6'),
0020 CMType = cms.string('TT6'),
0021 MaskTruncationCut = cms.double(0.05)
0022 ),
0023 UseFedKey = cms.untracked.bool(True),
0024 OutPutFileName = cms.string('SiStripPedestal.root')
0025 )
0026
0027