Back to home page

Project CMSSW displayed by LXR

 
 

    


File indexing completed on 2024-04-06 12:22:52

0001 <html>
0002   <head>
0003     <title>XML Documentation for ECAL DB numbering</title>
0004     <link rel="stylesheet" type="text/css" href="style.css"/>
0005   </head>
0006   <body>
0007 
0008     <div id=titleWindow> How to read this page:</div>
0009 
0010 
0011       <div class="numbering">
0012         <p>Part::"Name_of_part"</p>
0013         <p>Id Names::["id1_name","id2_name","id3_name"]</p>
0014         <p>Description::"Description of part and numbering scheme"</p>
0015         <p>Logic_ids::numbering logic in form of %10d number (X XXX XXX XXX with spaces separating the channel ids); channel ids used in logic (ordered)</p>
0016         <p>Channel_ids::[id1: range, id2: range, id3: range]</p>
0017         <p>Number of channels::number of channels of current part when DB is filled</p>
0018       </div>
0019 
0020 <ul>
0021     <li> NOTE #1: if z side is needed, assignment to logicId will be <br>
0022     z side = -1 --> sideIndex = 0;<br>
0023     z side = 1 --> sideIndex = 2;<br>
0024     </li>
0025 
0026     <li> NOTE #2: general idea for EE logicIds: a lower number (from 2 000 000 000 onwards) means that the part is bigger :) <br>Hierarchy: 
0027 
0028     <table>
0029         <tr> <td> TCC </td> <td> 1 XXX </td>
0030         <tr> <td> Whole Endcap  </td> <td>2 000 000 000 </td>
0031         <tr> <td> Sides </td> <td> 2 000 000 01X </td>
0032         <tr> <td> Dees </td> <td> 2 000 000 1XX </td>
0033         <tr> <td> Sectors </td> <td> 2 000 000 XXX Note: dee and sector logicIds don't overlap - 1st of the 3 free digits is 0 or 2 for sectors (=sideIndex) </td>
0034         <tr> <td> DCC </td> <td> 2 000 001 XXX </td>
0035         <tr> <td> Crystal number </td> <td> 2 01X XXX XXX </td>
0036         <tr> <td> Crystal hashed </td> <td> 2 02X XXX XXX </td>
0037         <tr> <td> Readout tower </td> <td> 2 000 0XX XXX </td>
0038         <tr> <td> Trigger tower </td> <td> 2 000 0XX XXX </td>
0039         <tr> <td> Readout tower strip </td> <td> 2 001 XXX XXX </td>
0040         <tr> <td> Trigger tower strip </td> <td> 2 001 XXX XXX </td>
0041         <tr> <td> Readout tower xtal strip </td> <td> 2 00X XXX XXX Note: trigger/readout tower (and xtal) strip logicIds don't overlap - 1st of the 7 free digits is 1 for trigger (=TCC), 6 for readout (=DCC) </td>
0042         <tr> <td> Trigger tower xtal strip </td> <td> 2 00X XXX XXX </td>
0043     </table>
0044 
0045     <li>
0046 
0047     <li>
0048 NOTE #3: ... = consecutive numbers
0049 
0050     </li>
0051     <li>
0052 NOTE #4  ~..= almost consecutive numbers (e.g. crystal number for x,y)
0053     </li>
0054     </ul>
0055 
0056   </body>
0057 </html>